7ZXG
Pfs48/45 bound to Fab fragment of monoclonal antibody 10D8
Experimental procedure
Experimental method | SINGLE WAVELENGTH |
Source type | SYNCHROTRON |
Source details | DIAMOND BEAMLINE I04 |
Synchrotron site | Diamond |
Beamline | I04 |
Temperature [K] | 100 |
Detector technology | PIXEL |
Collection date | 2016-10-02 |
Detector | DECTRIS EIGER2 X 16M |
Wavelength(s) | 0.92819 |
Spacegroup name | P 21 2 21 |
Unit cell lengths | 81.771, 125.803, 216.601 |
Unit cell angles | 90.00, 90.00, 90.00 |
Refinement procedure
Resolution | 65.360 - 4.200 |
R-factor | 0.261 |
Rwork | 0.259 |
R-free | 0.27610 |
Structure solution method | MOLECULAR REPLACEMENT |
Starting model (for MR) | 6h5n |
RMSD bond length | 0.003 |
RMSD bond angle | 0.642 |
Data reduction software | xia2 |
Data scaling software | xia2 |
Phasing software | PHASER |
Refinement software | PHENIX (1.19_4092) |
Data quality characteristics
Overall | Outer shell | |
Low resolution limit [Å] | 76.270 | 4.700 |
High resolution limit [Å] | 4.200 | 4.200 |
Rpim | 0.088 | 0.668 |
Number of reflections | 109594 | 31747 |
<I/σ(I)> | 7.5 | |
Completeness [%] | 99.9 | |
Redundancy | 6.5 | |
CC(1/2) | 0.998 | 0.543 |
Crystallization Conditions
crystal ID | method | pH | temperature | details |
1 | VAPOR DIFFUSION, SITTING DROP | 277 | 10 % (w/v) PEG 1000 and 10% (w/v) PEG 8000 |