6SBO
Estrogen receptor mutant L536S
Experimental procedure
Experimental method | SINGLE WAVELENGTH |
Source type | SYNCHROTRON |
Source details | SOLEIL BEAMLINE PROXIMA 1 |
Synchrotron site | SOLEIL |
Beamline | PROXIMA 1 |
Temperature [K] | 100 |
Detector technology | PIXEL |
Collection date | 2014-11-19 |
Detector | DECTRIS PILATUS3 6M |
Wavelength(s) | 0.978570 |
Spacegroup name | C 1 2 1 |
Unit cell lengths | 101.430, 57.710, 87.800 |
Unit cell angles | 90.00, 103.13, 90.00 |
Refinement procedure
Resolution | 49.830 - 1.480 |
R-factor | 0.191 |
Rwork | 0.190 |
R-free | 0.21200 |
Structure solution method | MOLECULAR REPLACEMENT |
RMSD bond length | 0.010 |
RMSD bond angle | 1.020 |
Data reduction software | XDS |
Data scaling software | Aimless |
Phasing software | PHASER |
Refinement software | BUSTER (2.11.7) |
Data quality characteristics
Overall | Outer shell | |
Low resolution limit [Å] | 49.830 | 1.628 |
High resolution limit [Å] | 1.480 | 1.484 |
Number of reflections | 57289 | 2865 |
<I/σ(I)> | 12.2 | |
Completeness [%] | 88.5 | |
Redundancy | 3 |
Crystallization Conditions
crystal ID | method | pH | temperature | details |
1 | VAPOR DIFFUSION, HANGING DROP | 298 | 22% PEG4000, NaCacodylate 0.1M pH 6.5, MgCl2 200mM |