6CDF
Human CtBP1 (28-378)
Experimental procedure
Experimental method | SINGLE WAVELENGTH |
Source type | ROTATING ANODE |
Source details | RIGAKU MICROMAX-007 HF |
Temperature [K] | 100 |
Detector technology | CCD |
Collection date | 2016-09-01 |
Detector | RIGAKU SATURN 944 |
Wavelength(s) | 1.54178 |
Spacegroup name | P 64 2 2 |
Unit cell lengths | 88.657, 88.657, 163.914 |
Unit cell angles | 90.00, 90.00, 120.00 |
Refinement procedure
Resolution | 38.991 - 2.600 |
R-factor | 0.2088 |
Rwork | 0.207 |
R-free | 0.24450 |
Structure solution method | MOLECULAR REPLACEMENT |
Starting model (for MR) | 4u6q |
RMSD bond length | 0.003 |
RMSD bond angle | 0.665 |
Data reduction software | HKL-2000 |
Data scaling software | HKL-2000 |
Phasing software | PHENIX |
Refinement software | PHENIX ((1.10_2155: ???)) |
Data quality characteristics
Overall | Outer shell | |
Low resolution limit [Å] | 50.000 | 2.690 |
High resolution limit [Å] | 2.600 | 2.600 |
Number of reflections | 15115 | |
<I/σ(I)> | 30.5 | |
Completeness [%] | 95.8 | |
Redundancy | 7.8 |
Crystallization Conditions
crystal ID | method | pH | temperature | details |
1 | VAPOR DIFFUSION, HANGING DROP | 7.5 | 293 | 5% PEG400, 140 mM calcium chloride |