CYP76AH1 from Salvia miltiorrhiza

Experimental procedure
Experimental methodSINGLE WAVELENGTH
Source typeSYNCHROTRON
Source detailsNFPSS BEAMLINE BL19U1
Synchrotron siteNFPSS
BeamlineBL19U1
Temperature [K]93
Detector technologyPIXEL
Collection date2015-12-28
DetectorDECTRIS PILATUS 6M
Wavelength(s)0.97853
Spacegroup nameP 31 2 1
Unit cell lengths108.776, 108.776, 105.990
Unit cell angles90.00, 90.00, 120.00
Refinement procedure
Resolution48.389 - 1.700
R-factor0.1389
Rwork0.137
R-free0.16817
RMSD bond length0.010
RMSD bond angle1.915
Data reduction softwareHKL-2000
Data scaling softwareHKL-2000
Phasing softwareMoRDa
Refinement softwareREFMAC (5.6.0117)
Data quality characteristics
 Overall
Low resolution limit [Å]50.000
High resolution limit [Å]1.700
Number of reflections79803
<I/σ(I)>24.15
Completeness [%]99.8
Redundancy6.5