Loading
PDBj
MenuPDBj@FacebookPDBj@TwitterPDBj@YouTubewwPDB FoundationwwPDB
RCSB PDBPDBeBMRBAdv. SearchSearch help

5JEM

Complex of IRF-3 with CBP

Experimental procedure
Experimental methodSINGLE WAVELENGTH
Source typeROTATING ANODE
Source detailsRIGAKU MICROMAX-007
Temperature [K]120
Detector technologyIMAGE PLATE
Collection date2015-10-25
DetectorRIGAKU RAXIS IV++
Wavelength(s)1.542
Spacegroup nameP 1 21 1
Unit cell lengths85.230, 88.660, 92.810
Unit cell angles90.00, 113.09, 90.00
Refinement procedure
Resolution36.992 - 2.500
R-factor0.1943
Rwork0.192
R-free0.24200
RMSD bond length0.003
RMSD bond angle0.624
Data reduction softwareMOSFLM
Data scaling softwareAimless
Phasing softwarePHASER
Refinement softwarePHENIX (1.9_1692)
Data quality characteristics
 Overall
Low resolution limit [Å]36.992
High resolution limit [Å]2.500
Number of reflections42426
<I/σ(I)>6.2
Completeness [%]96.3
Redundancy3.5
Crystallization Conditions
crystal IDmethodpHtemperaturedetails
1VAPOR DIFFUSION, HANGING DROP2770.1 M HEPES pH 7.5, 25% PEG 3350

218853

PDB entries from 2024-04-24

PDB statisticsPDBj update infoContact PDBjnumon