Loading
PDBj
MenuPDBj@FacebookPDBj@TwitterPDBj@YouTubewwPDB FoundationwwPDB
RCSB PDBPDBeBMRBAdv. SearchSearch help

3T8H

Thermolysin In Complex With UBTLN29

Experimental procedure
Experimental methodSINGLE WAVELENGTH
Source typeSYNCHROTRON
Source detailsBESSY BEAMLINE 14.2
Synchrotron siteBESSY
Beamline14.2
Temperature [K]100
Detector technologyCCD
Collection date2010-06-25
DetectorRAYONIX MX-225
Wavelength(s)0.91841
Spacegroup nameP 61 2 2
Unit cell lengths92.800, 92.800, 130.100
Unit cell angles90.00, 90.00, 120.00
Refinement procedure
Resolution40.184 - 1.450
R-factor0.1242
Rwork0.123
R-free0.15300
Structure solution methodMOLECULAR REPLACEMENT
Starting model (for MR)8tln
RMSD bond length0.011
RMSD bond angle1.047
Data reduction softwareHKL-2000
Data scaling softwareHKL-2000
Phasing softwarePHASER
Refinement softwarePHENIX ((phenix.refine: 1.7_650))
Data quality characteristics
 OverallOuter shell
Low resolution limit [Å]50.0001.480
High resolution limit [Å]1.4501.450
Number of reflections58688
<I/σ(I)>304.6
Completeness [%]99.599.1
Redundancy5.85.7
Crystallization Conditions
crystal IDmethodpHtemperaturedetails
1VAPOR DIFFUSION, SITTING DROP7.529150 mM Tris, 1.9 M cesium chloride, 50% DMSO, pH 7.5, VAPOR DIFFUSION, SITTING DROP, temperature 291K

219140

PDB entries from 2024-05-01

PDB statisticsPDBj update infoContact PDBjnumon