2V3H
Thrombin with 3-cycle no F
Experimental procedure
Experimental method | SINGLE WAVELENGTH |
Source type | ROTATING ANODE |
Source details | ENRAF-NONIUS FR571 |
Temperature [K] | 100 |
Detector technology | IMAGE PLATE |
Collection date | 1999-11-30 |
Detector | MARRESEARCH |
Spacegroup name | C 1 2 1 |
Unit cell lengths | 70.440, 71.780, 72.410 |
Unit cell angles | 90.00, 100.40, 90.00 |
Refinement procedure
Resolution | 71.250 - 1.790 |
R-factor | 0.175 |
Rwork | 0.173 |
R-free | 0.20700 |
Structure solution method | OTHER |
RMSD bond length | 0.013 |
RMSD bond angle | 1.340 |
Data reduction software | XDS |
Data scaling software | XDS |
Phasing software | CCP4 |
Refinement software | REFMAC (5.2.0019) |
Data quality characteristics
Overall | Outer shell | |
Low resolution limit [Å] | 50.000 | 1.900 |
High resolution limit [Å] | 1.790 | 1.790 |
Rmerge | 0.040 | 0.210 |
Number of reflections | 30755 | |
<I/σ(I)> | 48.1 | 12.8 |
Completeness [%] | 90.4 | 78 |
Redundancy | 2.74 | 2.71 |
Crystallization Conditions
crystal ID | method | pH | temperature | details |
1 |