2BNR
Structural and kinetic basis for heightened immunogenicity of T cell vaccines
Experimental procedure
Experimental method | SINGLE WAVELENGTH |
Source type | SYNCHROTRON |
Source details | ESRF BEAMLINE ID14-2 |
Synchrotron site | ESRF |
Beamline | ID14-2 |
Temperature [K] | 100 |
Detector technology | CCD |
Collection date | 2002-10-20 |
Detector | ADSC CCD |
Spacegroup name | P 1 21 1 |
Unit cell lengths | 72.563, 62.490, 116.955 |
Unit cell angles | 90.00, 105.34, 90.00 |
Refinement procedure
Resolution | 20.000 - 1.900 |
R-factor | 0.231 |
Rwork | 0.231 |
Structure solution method | MOLECULAR REPLACEMENT |
Starting model (for MR) | 1oga |
RMSD bond length | 0.006 |
RMSD bond angle | 1.656 |
Data reduction software | DENZO |
Data scaling software | SCALEPACK |
Phasing software | EPMR |
Refinement software | CNS (1.1) |
Data quality characteristics
Overall | Outer shell | |
Low resolution limit [Å] | 20.000 | 1.970 |
High resolution limit [Å] | 1.900 | 1.900 |
Rmerge | 0.060 | 0.450 |
Number of reflections | 87826 | |
<I/σ(I)> | 9.8 | 1.5 |
Completeness [%] | 98.5 | 96.6 |
Redundancy | 11 |
Crystallization Conditions
crystal ID | method | pH | temperature | details |
1 | 7.2 | pH 7.20 |