Loading
PDBj
MenuPDBj@FacebookPDBj@TwitterPDBj@YouTubewwPDB FoundationwwPDB
RCSB PDBPDBeBMRBAdv. SearchSearch help

1ANC

ANIONIC TRYPSIN MUTANT WITH SER 214 REPLACED BY LYS

Experimental procedure
Source typeROTATING ANODE
Source detailsRIGAKU RUH2R
Temperature [K]273
Detector technologyAREA DETECTOR
Collection date1990
DetectorSIEMENS
Spacegroup nameI 2 3
Unit cell lengths124.380, 124.380, 124.380
Unit cell angles90.00, 90.00, 90.00
Refinement procedure
Resolution7.000 - 2.200
R-factor0.154

*

Rwork0.154
Structure solution methodDIFFERENCE FOURIER
RMSD bond length0.012
RMSD bond angle3.100

*

Data reduction softwareXENGEN
Data scaling softwareXENGEN
Refinement softwarePROLSQ
Data quality characteristics
 Overall
High resolution limit [Å]2.200

*

Rmerge0.091

*

Total number of observations52900

*

Number of reflections17000
Crystallization Conditions
crystal IDmethodpHtemperaturedetails
18pH 8.0

219140

PDB entries from 2024-05-01

PDB statisticsPDBj update infoContact PDBjnumon