Loading
PDBj
MenuPDBj@FacebookPDBj@TwitterPDBj@YouTubewwPDB FoundationwwPDB
RCSB PDBPDBeBMRBAdv. SearchSearch help

7AEV

Pressure wave-exposed human hemoglobin: pump/probe data (3500 indexed images)

This is a non-PDB format compatible entry.
Summary for 7AEV
Entry DOI10.2210/pdb7aev/pdb
DescriptorHemoglobin subunit alpha, Hemoglobin subunit beta, PROTOPORPHYRIN IX CONTAINING FE, ... (5 entities in total)
Functional Keywordsxfel, sfx, high pressure crystallography, hemoglobin, oxygen transport
Biological sourceHomo sapiens (Human)
More
Total number of polymer chains4
Total formula weight63948.18
Authors
Barends, T.R.M.,Schlichting, I. (deposition date: 2020-09-18, release date: 2021-02-17, Last modification date: 2024-05-15)
Primary citationGrunbein, M.L.,Gorel, A.,Foucar, L.,Carbajo, S.,Colocho, W.,Gilevich, S.,Hartmann, E.,Hilpert, M.,Hunter, M.,Kloos, M.,Koglin, J.E.,Lane, T.J.,Lewandowski, J.,Lutman, A.,Nass, K.,Nass Kovacs, G.,Roome, C.M.,Sheppard, J.,Shoeman, R.L.,Stricker, M.,van Driel, T.,Vetter, S.,Doak, R.B.,Boutet, S.,Aquila, A.,Decker, F.J.,Barends, T.R.M.,Stan, C.A.,Schlichting, I.
Effect of X-ray free-electron laser-induced shockwaves on haemoglobin microcrystals delivered in a liquid jet.
Nat Commun, 12:1672-1672, 2021
Cited by
PubMed Abstract: X-ray free-electron lasers (XFELs) enable obtaining novel insights in structural biology. The recently available MHz repetition rate XFELs allow full data sets to be collected in shorter time and can also decrease sample consumption. However, the microsecond spacing of MHz XFEL pulses raises new challenges, including possible sample damage induced by shock waves that are launched by preceding pulses in the sample-carrying jet. We explored this matter with an X-ray-pump/X-ray-probe experiment employing haemoglobin microcrystals transported via a liquid jet into the XFEL beam. Diffraction data were collected using a shock-wave-free single-pulse scheme as well as the dual-pulse pump-probe scheme. The latter, relative to the former, reveals significant degradation of crystal hit rate, diffraction resolution and data quality. Crystal structures extracted from the two data sets also differ. Since our pump-probe attributes were chosen to emulate EuXFEL operation at its 4.5 MHz maximum pulse rate, this prompts concern about such data collection.
PubMed: 33723266
DOI: 10.1038/s41467-021-21819-8
PDB entries with the same primary citation
Experimental method
X-RAY DIFFRACTION (2.77 Å)
Structure validation

226707

數據於2024-10-30公開中

PDB statisticsPDBj update infoContact PDBjnumon