6JZH
Structure of human A2A adenosine receptor in complex with ZM241385 obtained from SFX experiments under atmospheric pressure
Summary for 6JZH
Entry DOI | 10.2210/pdb6jzh/pdb |
Descriptor | Adenosine receptor A2a,Soluble cytochrome b562,Adenosine receptor A2a, SODIUM ION, 4-{2-[(7-amino-2-furan-2-yl[1,2,4]triazolo[1,5-a][1,3,5]triazin-5-yl)amino]ethyl}phenol, ... (6 entities in total) |
Functional Keywords | x-ray free-electron lasers room-temperature g-protein-coupled receptor, membrane protein |
Biological source | Homo sapiens (Human) More |
Total number of polymer chains | 1 |
Total formula weight | 56875.35 |
Authors | Nango, E.,Shimamura, T.,Nakane, T.,Yamanaka, Y.,Mori, C.,Kimura, K.T.,Fujiwara, T.,Tanaka, T.,Iwata, S. (deposition date: 2019-05-02, release date: 2019-10-30, Last modification date: 2024-10-16) |
Primary citation | Shimazu, Y.,Tono, K.,Tanaka, T.,Yamanaka, Y.,Nakane, T.,Mori, C.,Terakado Kimura, K.,Fujiwara, T.,Sugahara, M.,Tanaka, R.,Doak, R.B.,Shimamura, T.,Iwata, S.,Nango, E.,Yabashi, M. High-viscosity sample-injection device for serial femtosecond crystallography at atmospheric pressure. J.Appl.Crystallogr., 52:1280-1288, 2019 Cited by PubMed Abstract: A sample-injection device has been developed at SPring-8 Angstrom Compact Free-Electron Laser (SACLA) for serial femtosecond crystallography (SFX) at atmospheric pressure. Microcrystals embedded in a highly viscous carrier are stably delivered from a capillary nozzle with the aid of a coaxial gas flow and a suction device. The cartridge-type sample reservoir is easily replaceable and facilitates sample reloading or exchange. The reservoir is positioned in a cooling jacket with a temperature-regulated water flow, which is useful to prevent drastic changes in the sample temperature during data collection. This work demonstrates that the injector successfully worked in SFX of the human A adenosine receptor complexed with an antagonist, ZM241385, in lipidic cubic phase and for hen egg-white lysozyme microcrystals in a grease carrier. The injection device has also been applied to many kinds of proteins, not only for static structural analyses but also for dynamics studies using pump-probe techniques. PubMed: 31798359DOI: 10.1107/S1600576719012846 PDB entries with the same primary citation |
Experimental method | X-RAY DIFFRACTION (2.25 Å) |
Structure validation
Download full validation report