4S1D
Structure of IgG1 Fab fragment in complex with Biotincytidinamide
Summary for 4S1D
Entry DOI | 10.2210/pdb4s1d/pdb |
Descriptor | MAB M33 FAB FRAGMENT, heavy chain, MAB M33 FAB FRAGMENT, light chain, N~6~-{5-[(3aS,4S,6aR)-2-oxohexahydro-1H-thieno[3,4-d]imidazol-4-yl]pentanoyl}-L-lysinamide, ... (5 entities in total) |
Functional Keywords | antibody, fab fragment, hapten, mab_m33_fab_fragment, immune system |
Biological source | Mus musculus (mouse) More |
Total number of polymer chains | 8 |
Total formula weight | 191160.23 |
Authors | Dengl, S.,Hoffmann, E.,Grote, M.,Wagner, C.,Mundigl, O.,Georges, G.,Theorey, I.,Stubenrauch, K.-G.,Bujotzek, A.,Josel, H.-P.,Dziadek, S.,Benz, J.,Brinkmann, U. (deposition date: 2015-01-13, release date: 2015-03-04, Last modification date: 2024-10-09) |
Primary citation | Dengl, S.,Hoffmann, E.,Grote, M.,Wagner, C.,Mundigl, O.,Georges, G.,Thorey, I.,Stubenrauch, K.G.,Bujotzek, A.,Josel, H.P.,Dziadek, S.,Benz, J.,Brinkmann, U. Hapten-directed spontaneous disulfide shuffling: a universal technology for site-directed covalent coupling of payloads to antibodies. Faseb J., 29:1763-1779, 2015 Cited by PubMed Abstract: Humanized hapten-binding IgGs were designed with an accessible cysteine close to their binding pockets, for specific covalent payload attachment. Individual analyses of known structures of digoxigenin (Dig)- and fluorescein (Fluo) binding antibodies and a new structure of a biotin (Biot)-binder, revealed a "universal" coupling position (52(+2)) in proximity to binding pockets but without contributing to hapten interactions. Payloads that carry a free thiol are positioned on the antibody and covalently linked to it via disulfides. Covalent coupling is achieved and driven toward complete (95-100%) payload occupancy by spontaneous redox shuffling between antibody and payload. Attachment at the universal position works with different haptens, antibodies, and payloads. Examples are the haptens Fluo, Dig, and Biot combined with various fluorescent or peptidic payloads. Disulfide-bonded covalent antibody-payload complexes do not dissociate in vitro and in vivo. Coupling requires the designed cysteine and matching payload thiol because payload or antibody without the Cys/thiol are not linked (<5% nonspecific coupling). Hapten-mediated positioning is necessary as hapten-thiol-payload is only coupled to antibodies that bind matching haptens. Covalent complexes are more stable in vivo than noncovalent counterparts because digoxigeninylated or biotinylated fluorescent payloads without disulfide-linkage are cleared more rapidly in mice (approximately 50% reduced 48 hour serum levels) compared with their covalently linked counterparts. The coupling technology is applicable to many haptens and hapten binding antibodies (confirmed by automated analyses of the structures of 140 additional hapten binding antibodies) and can be applied to modulate the pharmacokinetics of small compounds or peptides. It is also suitable to link payloads in a reduction-releasable manner to tumor- or tissue-targeting delivery vehicles. PubMed: 25670234DOI: 10.1096/fj.14-263665 PDB entries with the same primary citation |
Experimental method | X-RAY DIFFRACTION (2.5 Å) |
Structure validation
Download full validation report
