Loading
PDBj
MenuPDBj@FacebookPDBj@TwitterPDBj@YouTubewwPDB FoundationwwPDB
RCSB PDBPDBeBMRBAdv. SearchSearch help

2LPS

Molecular dynamics re-refinement of domain 5 of the yeast ai5(gamma) group II intron

Summary for 2LPS
Entry DOI10.2210/pdb2lps/pdb
Related1kxk 2LPT
DescriptorRNA (34-MER) (1 entity in total)
Functional Keywordsrna, tetraloop, bulge
Total number of polymer chains1
Total formula weight10970.57
Authors
Henriksen, N.M.,Davis, D.R.,Cheatham III, T.E. (deposition date: 2012-02-17, release date: 2012-08-08, Last modification date: 2024-05-01)
Primary citationHenriksen, N.M.,Davis, D.R.,Cheatham Iii, T.E.
Molecular dynamics re-refinement of two different small RNA loop structures using the original NMR data suggest a common structure.
J.Biomol.Nmr, 53:321-339, 2012
Cited by
PubMed Abstract: Restrained molecular dynamics simulations are a robust, though perhaps underused, tool for the end-stage refinement of biomolecular structures. We demonstrate their utility-using modern simulation protocols, optimized force fields, and inclusion of explicit solvent and mobile counterions-by re-investigating the solution structures of two RNA hairpins that had previously been refined using conventional techniques. The structures, both domain 5 group II intron ribozymes from yeast ai5γ and Pylaiella littoralis, share a nearly identical primary sequence yet the published 3D structures appear quite different. Relatively long restrained MD simulations using the original NMR restraint data identified the presence of a small set of violated distance restraints in one structure and a possibly incorrect trapped bulge nucleotide conformation in the other structure. The removal of problematic distance restraints and the addition of a heating step yielded representative ensembles with very similar 3D structures and much lower pairwise RMSD values. Analysis of ion density during the restrained simulations helped to explain chemical shift perturbation data published previously. These results suggest that restrained MD simulations, with proper caution, can be used to "update" older structures or aid in the refinement of new structures that lack sufficient experimental data to produce a high quality result. Notable cautions include the need for sufficient sampling, awareness of potential force field bias (such as small angle deviations with the current AMBER force fields), and a proper balance between the various restraint weights.
PubMed: 22714631
DOI: 10.1007/s10858-012-9642-5
PDB entries with the same primary citation
Experimental method
SOLUTION NMR
Structure validation

226707

건을2024-10-30부터공개중

PDB statisticsPDBj update infoContact PDBjnumon