Experimental procedure
| Experimental method | MAD |
| Source type | SYNCHROTRON |
| Source details | APS BEAMLINE 21-ID-D |
| Synchrotron site | APS |
| Beamline | 21-ID-D |
| Temperature [K] | 296 |
| Detector technology | PIXEL |
| Collection date | 2016-08-26 |
| Detector | DECTRIS EIGER X 9M |
| Wavelength(s) | 1.1 |
| Spacegroup name | P 21 21 21 |
| Unit cell lengths | 41.772, 59.480, 108.162 |
| Unit cell angles | 90.00, 90.00, 90.00 |
Refinement procedure
| Resolution | 40.010 - 1.480 |
| R-factor | 0.1946 |
| Rwork | 0.193 |
| R-free | 0.22790 |
| Structure solution method | MOLECULAR REPLACEMENT |
| RMSD bond length | 0.007 |
| RMSD bond angle | 1.128 |
| Data reduction software | DENZO |
| Data scaling software | SCALEPACK |
| Phasing software | PHASER |
| Refinement software | PHENIX (1.20.1_4487) |
Data quality characteristics
| Overall | Outer shell | |
| Low resolution limit [Å] | 54.800 | 1.560 |
| High resolution limit [Å] | 1.480 | 1.480 |
| Number of reflections | 275217 | 44857 |
| <I/σ(I)> | 13.6 | 2.5 |
| Completeness [%] | 90.6 | 100 |
| Redundancy | 6.6 | 6.8 |
Crystallization Conditions
| crystal ID | method | pH | temperature | details |
| 1 | VAPOR DIFFUSION, SITTING DROP | 296 | 100 mM Magnesium Formate and 15% PEG 3350. |