HeliScrew4

Experimental procedure
Experimental methodSINGLE WAVELENGTH
Source typeSYNCHROTRON
Source detailsAPS BEAMLINE 24-ID-E
Synchrotron siteAPS
Beamline24-ID-E
Temperature [K]100
Detector technologyPIXEL
Collection date2025-10-26
DetectorDECTRIS EIGER X 16M
Wavelength(s)0.980
Spacegroup nameP 1 21 1
Unit cell lengths37.339, 62.620, 45.980
Unit cell angles90.00, 96.42, 90.00
Refinement procedure
Resolution45.690 - 2.200
R-factor0.2009
Rwork0.197
R-free0.23690
Structure solution methodMOLECULAR REPLACEMENT
RMSD bond length0.008
RMSD bond angle1.076
Data reduction softwareRAPD
Data scaling softwareRAPD
Phasing softwarePHASER
Refinement softwarePHENIX (1.21.2_5419)
Data quality characteristics
 OverallOuter shell
Low resolution limit [Å]45.6902.090
High resolution limit [Å]2.0462.050
Rmeas0.344
Rpim0.1430.509
Number of reflections68979765
<I/σ(I)>5.293.17
Completeness [%]92.491.24
Redundancy5.45.6
CC(1/2)0.9500.392
Crystallization Conditions
crystal IDmethodpHtemperaturedetails
1VAPOR DIFFUSION, HANGING DROP72931.8 M ammonium citrate tribasic, pH 7.0

256789