Experimental procedure
| Experimental method | SINGLE WAVELENGTH |
| Source type | SYNCHROTRON |
| Source details | DIAMOND BEAMLINE I04 |
| Synchrotron site | Diamond |
| Beamline | I04 |
| Temperature [K] | 103 |
| Detector technology | PIXEL |
| Collection date | 2020-03-02 |
| Detector | DECTRIS EIGER X 16M |
| Wavelength(s) | 0.9795 |
| Spacegroup name | P 21 21 21 |
| Unit cell lengths | 47.682, 79.906, 92.240 |
| Unit cell angles | 90.00, 90.00, 90.00 |
Refinement procedure
| Resolution | 29.080 - 2.100 |
| R-factor | 0.16967 |
| Rwork | 0.166 |
| R-free | 0.22993 |
| Structure solution method | MOLECULAR REPLACEMENT |
| RMSD bond length | 0.002 |
| RMSD bond angle | 0.847 |
| Data reduction software | DIALS |
| Data scaling software | Aimless |
| Phasing software | REFMAC |
| Refinement software | REFMAC (5.8.0430) |
Data quality characteristics
| Overall | Outer shell | |
| Low resolution limit [Å] | 29.080 | 2.160 |
| High resolution limit [Å] | 2.100 | 2.100 |
| Rmerge | 0.066 | 0.651 |
| Rmeas | 0.073 | 0.735 |
| Rpim | 0.032 | 0.333 |
| Total number of observations | 8064 | |
| Number of reflections | 20964 | 1729 |
| <I/σ(I)> | 12.1 | 2 |
| Completeness [%] | 99.0 | |
| Redundancy | 4.9 | 4.7 |
| CC(1/2) | 0.999 | 0.757 |
Crystallization Conditions
| crystal ID | method | pH | temperature | details |
| 1 | VAPOR DIFFUSION, SITTING DROP | 7.4 | 293 | 8% PEG 4000 0.1 M HEPES, pH 8.2 |