Experimental procedure
| Experimental method | SINGLE WAVELENGTH |
| Source type | SYNCHROTRON |
| Source details | NSLS-II BEAMLINE 17-ID-2 |
| Synchrotron site | NSLS-II |
| Beamline | 17-ID-2 |
| Temperature [K] | 100 |
| Detector technology | PIXEL |
| Collection date | 2020-11-05 |
| Detector | DECTRIS EIGER X 9M |
| Wavelength(s) | 0.92011 |
| Spacegroup name | P 1 |
| Unit cell lengths | 60.553, 61.021, 73.919 |
| Unit cell angles | 71.21, 75.06, 71.85 |
Refinement procedure
| Resolution | 28.680 - 1.700 |
| R-factor | 0.1753 |
| Rwork | 0.174 |
| R-free | 0.21430 |
| Structure solution method | MOLECULAR REPLACEMENT |
| RMSD bond length | 0.007 |
| RMSD bond angle | 0.846 |
| Data reduction software | XDS |
| Data scaling software | Aimless |
| Phasing software | PHASER |
| Refinement software | PHENIX (1.20.1_4487) |
Data quality characteristics
| Overall | Outer shell | |
| Low resolution limit [Å] | 28.680 | 1.760 |
| High resolution limit [Å] | 1.700 | 1.700 |
| Number of reflections | 99668 | 9892 |
| <I/σ(I)> | 7.26 | |
| Completeness [%] | 97.7 | |
| Redundancy | 3.5 | |
| CC(1/2) | 0.992 | 0.784 |
Crystallization Conditions
| crystal ID | method | pH | temperature | details |
| 1 | VAPOR DIFFUSION, HANGING DROP | 7.5 | 293 | 100mM Tris pH 7.5, 10% PEG3350, 200mM Proline |