Experimental procedure
| Experimental method | SINGLE WAVELENGTH |
| Source type | SYNCHROTRON |
| Source details | SPRING-8 BEAMLINE BL32XU |
| Synchrotron site | SPring-8 |
| Beamline | BL32XU |
| Temperature [K] | 100 |
| Detector technology | PIXEL |
| Collection date | 2025-04-29 |
| Detector | DECTRIS EIGER X 9M |
| Wavelength(s) | 1 |
| Spacegroup name | P 21 21 21 |
| Unit cell lengths | 64.350, 75.310, 85.610 |
| Unit cell angles | 90.00, 90.00, 90.00 |
Refinement procedure
| Resolution | 48.920 - 1.390 |
| R-factor | 0.1795 |
| Rwork | 0.179 |
| R-free | 0.19500 |
| Structure solution method | MOLECULAR REPLACEMENT |
| RMSD bond length | 0.009 |
| RMSD bond angle | 1.035 |
| Data reduction software | XDS |
| Data scaling software | XSCALE |
| Phasing software | MOLREP |
| Refinement software | PHENIX ((1.21.1_5286: ???)) |
Data quality characteristics
| Overall | Outer shell | |
| Low resolution limit [Å] | 48.920 | 1.420 |
| High resolution limit [Å] | 1.390 | 1.390 |
| Number of reflections | 161449 | 11386 |
| <I/σ(I)> | 9.6 | |
| Completeness [%] | 99.9 | |
| Redundancy | 4.4 | |
| CC(1/2) | 0.997 | 0.426 |
Crystallization Conditions
| crystal ID | method | pH | temperature | details |
| 1 | VAPOR DIFFUSION, SITTING DROP | 298 | 0.2M sodium malonate pH 7.0, 20% PEG 3350 |