9VE4
The MIDN Catch-IRF4 fusion protein
Experimental procedure
| Experimental method | SINGLE WAVELENGTH |
| Source type | SYNCHROTRON |
| Source details | SSRF BEAMLINE BL10U2 |
| Synchrotron site | SSRF |
| Beamline | BL10U2 |
| Temperature [K] | 193 |
| Detector technology | PIXEL |
| Collection date | 2024-12-01 |
| Detector | DECTRIS EIGER X 16M |
| Wavelength(s) | 0.97918 |
| Spacegroup name | P 65 2 2 |
| Unit cell lengths | 88.640, 88.640, 72.270 |
| Unit cell angles | 90.00, 90.00, 120.00 |
Refinement procedure
| Resolution | 26.310 - 2.550 |
| R-factor | 0.2323 |
| Rwork | 0.230 |
| R-free | 0.28100 |
| Structure solution method | MOLECULAR REPLACEMENT |
| RMSD bond length | 0.008 |
| RMSD bond angle | 1.131 |
| Data reduction software | xia2 |
| Phasing software | PHASER |
| Refinement software | PHENIX (1.21.2_5419) |
Data quality characteristics
| Overall | Outer shell | |
| Low resolution limit [Å] | 26.310 | 2.620 |
| High resolution limit [Å] | 2.550 | 2.550 |
| Number of reflections | 5717 | 566 |
| <I/σ(I)> | 29.9 | |
| Completeness [%] | 97.8 | |
| Redundancy | 35.8 | |
| CC(1/2) | 1.000 | 0.990 |
Crystallization Conditions
| crystal ID | method | pH | temperature | details |
| 1 | VAPOR DIFFUSION, HANGING DROP | 289 | 6% (v/v) tacsimate (pH 4.0) and 12% (w/v) polyethylene glycol (PEG) 3,350 |