Loading
PDBj
MenuPDBj@FacebookPDBj@X(formerly Twitter)PDBj@BlueSkyPDBj@YouTubewwPDB FoundationwwPDBDonate
RCSB PDBPDBeBMRBAdv. SearchSearch help

9V5E

Light driven CO2 reduction by fluorescent protein mRuby-CO2M4

Experimental procedure
Experimental methodSINGLE WAVELENGTH
Source typeSYNCHROTRON
Source detailsSSRF BEAMLINE BL02U1
Synchrotron siteSSRF
BeamlineBL02U1
Temperature [K]100
Detector technologyPIXEL
Collection date2024-10-02
DetectorDECTRIS EIGER2 S 9M
Wavelength(s)0.97918
Spacegroup nameP 21 21 21
Unit cell lengths68.335, 97.555, 31.964
Unit cell angles90.00, 90.00, 90.00
Refinement procedure
Resolution34.170 - 1.920
R-factor0.23346
Rwork0.232
R-free0.26261
Structure solution methodMOLECULAR REPLACEMENT
RMSD bond length0.004
RMSD bond angle1.271
Data reduction softwareXDS
Data scaling softwareAimless
Phasing softwareMOLREP
Refinement softwareREFMAC (5.8.0430)
Data quality characteristics
 OverallOuter shell
Low resolution limit [Å]34.1901.970
High resolution limit [Å]1.9201.920
Number of reflections170651225
<I/σ(I)>7.4
Completeness [%]100.0
Redundancy12.1
CC(1/2)0.9970.792
Crystallization Conditions
crystal IDmethodpHtemperaturedetails
1VAPOR DIFFUSION, SITTING DROP2930.2M NH4HCO3, 0.2M (NH4)2SO4, 0.1M Bistris pH6.5, 24%PEG3350

254917

PDB entries from 2026-06-10

PDB statisticsPDBj update infoContact PDBjnumon