9UUV
beta barrel protein-LucK
Experimental procedure
| Experimental method | SINGLE WAVELENGTH |
| Source type | SYNCHROTRON |
| Source details | SSRF BEAMLINE BL10U2 |
| Synchrotron site | SSRF |
| Beamline | BL10U2 |
| Temperature [K] | 100 |
| Detector technology | PIXEL |
| Collection date | 2023-05-18 |
| Detector | DECTRIS EIGER X 16M |
| Wavelength(s) | 0.97856 |
| Spacegroup name | P 21 21 21 |
| Unit cell lengths | 46.399, 83.073, 88.057 |
| Unit cell angles | 90.00, 90.00, 90.00 |
Refinement procedure
| Resolution | 31.940 - 1.870 |
| R-factor | 0.1949 |
| Rwork | 0.193 |
| R-free | 0.22420 |
| Structure solution method | MOLECULAR REPLACEMENT |
| RMSD bond length | 0.011 |
| RMSD bond angle | 1.096 |
| Data reduction software | XDS |
| Data scaling software | XDS |
| Phasing software | PHENIX |
| Refinement software | PHENIX (1.20.1_4487) |
Data quality characteristics
| Overall | Outer shell | |
| Low resolution limit [Å] | 60.430 | 1.970 |
| High resolution limit [Å] | 1.870 | 1.870 |
| Rmerge | 0.044 | 0.450 |
| Number of reflections | 28635 | 3984 |
| <I/σ(I)> | 22.7 | |
| Completeness [%] | 99.6 | |
| Redundancy | 7.3 | |
| CC(1/2) | 0.999 | 0.841 |
Crystallization Conditions
| crystal ID | method | pH | temperature | details |
| 1 | VAPOR DIFFUSION, SITTING DROP | 291.15 | 0.2 M Lithium sulfate, 0.1 M Tris 8.5, 30 % w/v PEG 4000 |