Experimental procedure
| Experimental method | SINGLE WAVELENGTH |
| Source type | SYNCHROTRON |
| Source details | SSRF BEAMLINE BL02U1 |
| Synchrotron site | SSRF |
| Beamline | BL02U1 |
| Temperature [K] | 100 |
| Detector technology | PIXEL |
| Collection date | 2022-09-19 |
| Detector | DECTRIS EIGER2 X 9M |
| Wavelength(s) | 0.979 |
| Spacegroup name | P 1 21 1 |
| Unit cell lengths | 72.773, 66.112, 92.600 |
| Unit cell angles | 90.00, 103.43, 90.00 |
Refinement procedure
| Resolution | 37.247 - 1.999 |
| Rwork | 0.211 |
| R-free | 0.24050 |
| Structure solution method | MOLECULAR REPLACEMENT |
| RMSD bond length | 0.007 |
| RMSD bond angle | 1.751 |
| Data reduction software | XDS |
| Data scaling software | XDS |
| Phasing software | PHASER |
| Refinement software | REFMAC (5.8.0430) |
Data quality characteristics
| Overall | Outer shell | |
| Low resolution limit [Å] | 50.000 | 2.030 |
| High resolution limit [Å] | 1.999 | 1.999 |
| Rmerge | 0.104 | |
| Number of reflections | 57418 | 4125 |
| <I/σ(I)> | 29.371 | |
| Completeness [%] | 98.9 | |
| Redundancy | 5.9 | |
| CC(1/2) | 0.822 |
Crystallization Conditions
| crystal ID | method | pH | temperature | details |
| 1 | VAPOR DIFFUSION, SITTING DROP | 289.15 | 30% PEG400 100 mM Tris base/ Hydrochloric acid pH 8.5 200 mM Magnesium chloride |