Experimental procedure
| Experimental method | SINGLE WAVELENGTH |
| Source type | SYNCHROTRON |
| Source details | SSRF BEAMLINE BL19U1 |
| Synchrotron site | SSRF |
| Beamline | BL19U1 |
| Temperature [K] | 100 |
| Detector technology | PIXEL |
| Collection date | 2024-04-19 |
| Detector | DECTRIS PILATUS 6M |
| Wavelength(s) | 1.00000 |
| Spacegroup name | P 21 21 21 |
| Unit cell lengths | 104.000, 159.420, 171.990 |
| Unit cell angles | 90.00, 90.00, 90.00 |
Refinement procedure
| Resolution | 59.380 - 2.930 |
| R-factor | 0.2165 |
| Rwork | 0.214 |
| R-free | 0.26930 |
| Structure solution method | MOLECULAR REPLACEMENT |
| RMSD bond length | 0.006 |
| RMSD bond angle | 1.010 |
| Data reduction software | HKL-3000 |
| Data scaling software | xia2 |
| Phasing software | HKL-3000 |
| Refinement software | PHENIX (1.18.2_3874) |
Data quality characteristics
| Overall | Outer shell | |
| Low resolution limit [Å] | 59.380 | 3.010 |
| High resolution limit [Å] | 2.930 | 2.930 |
| Number of reflections | 50153 | 4031 |
| <I/σ(I)> | 8 | |
| Completeness [%] | 81.9 | |
| Redundancy | 5.5 | |
| CC(1/2) | 0.994 | 0.615 |
Crystallization Conditions
| crystal ID | method | pH | temperature | details |
| 1 | VAPOR DIFFUSION, HANGING DROP | 293 | 6% PEG 4000, 5% glycerol, 0.1M MES, 30mM CaCl2, 30mM MgCl2, pH 6.7 |