Experimental procedure
| Experimental method | SINGLE WAVELENGTH |
| Source type | SYNCHROTRON |
| Source details | ESRF BEAMLINE ID23-2 |
| Synchrotron site | ESRF |
| Beamline | ID23-2 |
| Temperature [K] | 100 |
| Detector technology | PIXEL |
| Collection date | 2023-06-16 |
| Detector | DECTRIS EIGER2 X 9M |
| Wavelength(s) | 0.8731 |
| Spacegroup name | P 21 21 21 |
| Unit cell lengths | 68.337, 68.751, 138.953 |
| Unit cell angles | 90.00, 90.00, 90.00 |
Refinement procedure
| Resolution | 69.480 - 2.300 |
| R-factor | 0.1977 |
| Rwork | 0.195 |
| R-free | 0.24980 |
| Structure solution method | MOLECULAR REPLACEMENT |
| RMSD bond length | 0.012 |
| RMSD bond angle | 1.198 |
| Data reduction software | autoPROC |
| Data scaling software | autoPROC |
| Phasing software | PHASER |
| Refinement software | PHENIX ((1.21-5207-000)) |
Data quality characteristics
| Overall | Outer shell | |
| Low resolution limit [Å] | 69.480 | 2.340 |
| High resolution limit [Å] | 2.300 | 2.300 |
| Number of reflections | 28859 | 1454 |
| <I/σ(I)> | 7.8 | 1.7 |
| Completeness [%] | 96.5 | 100 |
| Redundancy | 10.9 | 10.8 |
| CC(1/2) | 0.989 | 0.467 |
Crystallization Conditions
| crystal ID | method | pH | temperature | details |
| 1 | VAPOR DIFFUSION, HANGING DROP | 291.15 | 1.26 M sodium phosphate monobasic, 0.14 M potassium phosphate dibasic |