Loading
PDBj
MenuPDBj@FacebookPDBj@X(formerly Twitter)PDBj@BlueSkyPDBj@YouTubewwPDB FoundationwwPDBDonate
RCSB PDBPDBeBMRBAdv. SearchSearch help

9QF7

PRMT2 in complex with aDMA analog

This is a non-PDB format compatible entry.
Experimental procedure
Experimental methodSINGLE WAVELENGTH
Source typeSYNCHROTRON
Source detailsSOLEIL BEAMLINE PROXIMA 1
Synchrotron siteSOLEIL
BeamlinePROXIMA 1
Temperature [K]100
Detector technologyPIXEL
Collection date2022-06-15
DetectorDECTRIS EIGER X 16M
Wavelength(s)0.979
Spacegroup nameC 2 2 21
Unit cell lengths65.727, 114.561, 132.721
Unit cell angles90.00, 90.00, 90.00
Refinement procedure
Resolution29.560 - 2.270
R-factor0.1941
Rwork0.192
R-free0.23370
Structure solution methodMOLECULAR REPLACEMENT
RMSD bond length0.010
RMSD bond angle0.874
Data reduction softwareXDS
Data scaling softwareAimless
Phasing softwarePHENIX
Refinement softwarePHENIX ((1.21rc1_5015: ???))
Data quality characteristics
 OverallOuter shell
Low resolution limit [Å]29.5602.340
High resolution limit [Å]2.2702.270
Rmerge0.1222.217
Rmeas0.1272.315
Rpim0.0350.654
Number of reflections232651805
<I/σ(I)>13.71
Completeness [%]98.684.9
Redundancy13.412.3
CC(1/2)0.9990.575
Crystallization Conditions
crystal IDmethodpHtemperaturedetails
1VAPOR DIFFUSION, HANGING DROP5.329324% peg3350, 100 mM BT pH5.3, 0.1M Li2SO4

251422

PDB entries from 2026-04-01

PDB statisticsPDBj update infoContact PDBjnumon