9P12
Lysozyme Room-Temperature In-Situ, Shipped
Experimental procedure
| Experimental method | SINGLE WAVELENGTH |
| Source type | SYNCHROTRON |
| Source details | DIAMOND BEAMLINE VMXi |
| Synchrotron site | Diamond |
| Beamline | VMXi |
| Temperature [K] | 293 |
| Detector technology | PIXEL |
| Collection date | 2024-10-03 |
| Detector | DECTRIS EIGER2 X 4M |
| Wavelength(s) | 0.7749 |
| Spacegroup name | P 43 21 2 |
| Unit cell lengths | 78.668, 78.668, 37.683 |
| Unit cell angles | 90.00, 90.00, 90.00 |
Refinement procedure
| Resolution | 55.600 - 1.570 |
| Rwork | 0.162 |
| R-free | 0.20330 |
| Structure solution method | MOLECULAR REPLACEMENT |
| RMSD bond length | 0.015 |
| RMSD bond angle | 2.198 |
| Data reduction software | xia2.multiplex |
| Data scaling software | Aimless |
| Phasing software | MOLREP |
| Refinement software | REFMAC (5.8.0425) |
Data quality characteristics
| Overall | Inner shell | Outer shell | |
| Low resolution limit [Å] | 55.600 | 55.630 | 1.600 |
| High resolution limit [Å] | 1.570 | 8.600 | 1.570 |
| Rmerge | 0.071 | 0.020 | 1.153 |
| Rmeas | 0.075 | 0.021 | 1.436 |
| Rpim | 0.023 | 0.006 | 0.840 |
| Number of reflections | 17048 | 17048 | 796 |
| <I/σ(I)> | 20.7 | ||
| Completeness [%] | 99.8 | ||
| Redundancy | 15.8 | 14.9 | 4 |
| CC(1/2) | 1.000 | 1.000 | 0.428 |
Crystallization Conditions
| crystal ID | method | pH | temperature | details |
| 1 | VAPOR DIFFUSION, SITTING DROP | 4 | 295 | 0.78 M sodium chloride, 0.1 M sodium acetate |