9NW8
CA117v2v8 Fab bound to HLA-E-Mtb44
Experimental procedure
| Experimental method | SINGLE WAVELENGTH |
| Source type | SYNCHROTRON |
| Source details | APS BEAMLINE 22-ID |
| Synchrotron site | APS |
| Beamline | 22-ID |
| Temperature [K] | 80 |
| Detector technology | PIXEL |
| Collection date | 2022-10-09 |
| Detector | DECTRIS EIGER X 16M |
| Wavelength(s) | 1.000 |
| Spacegroup name | P 1 21 1 |
| Unit cell lengths | 57.730, 72.330, 121.270 |
| Unit cell angles | 90.00, 101.36, 90.00 |
Refinement procedure
| Resolution | 59.450 - 2.300 |
| R-factor | 0.1983 |
| Rwork | 0.196 |
| R-free | 0.24570 |
| Structure solution method | MOLECULAR REPLACEMENT |
| RMSD bond length | 0.009 |
| RMSD bond angle | 0.891 |
| Data reduction software | MOSFLM |
| Data scaling software | Aimless |
| Phasing software | PHASER |
| Refinement software | PHENIX (dev_3758) |
Data quality characteristics
| Overall | Outer shell | |
| Low resolution limit [Å] | 61.590 | 2.380 |
| High resolution limit [Å] | 2.300 | 2.300 |
| Number of reflections | 42884 | 4178 |
| <I/σ(I)> | 5.7 | 0.7 |
| Completeness [%] | 98.6 | |
| Redundancy | 3.4 | |
| CC(1/2) | 0.989 | 0.312 |
Crystallization Conditions
| crystal ID | method | pH | temperature | details |
| 1 | VAPOR DIFFUSION, SITTING DROP | 293 | 0.2 M magnesium acetate, 20% PEG 3350 |