9NMM

[4,7,9-1] Shifted tensegrity triangle with an (arm,center,arm) distribution of (4,7,9) base pairs and 1 nt sticky ends

Experimental procedure
Experimental methodSINGLE WAVELENGTH
Source typeSYNCHROTRON
Source detailsAPS BEAMLINE 17-ID
Synchrotron siteAPS
Beamline17-ID
Temperature [K]100
Detector technologyPIXEL
Collection date2023-03-19
DetectorDECTRIS EIGER2 X 9M
Wavelength(s)0.991870
Spacegroup nameH 3
Unit cell lengths108.163, 108.163, 86.308
Unit cell angles90.00, 90.00, 120.00
Refinement procedure
Resolution32.760 - 4.860
R-factor0.1372
Rwork0.135
R-free0.17220
Structure solution methodMOLECULAR REPLACEMENT
RMSD bond length0.007
RMSD bond angle0.886
Data reduction softwareautoPROC
Data scaling softwareSTARANISO
Phasing softwarePHASER
Refinement softwarePHENIX (1.20.1_4487)
Data quality characteristics
 OverallInner shellOuter shell
Low resolution limit [Å]63.47363.4735.665
High resolution limit [Å]4.85710.1244.857
Number of reflections1176195198
<I/σ(I)>6.5
Completeness [%]84.4
Redundancy9.5
CC(1/2)0.9990.9990.429
Crystallization Conditions
crystal IDmethodpHtemperaturedetails
1VAPOR DIFFUSION, HANGING DROP293100 mM MOPS, 1.25 M magnesium sulfate

246031