9NKA
[-1,8,12-->14] Shifted tensegrity triangle with an (arm,center,arm) distribution of (-1,8,12) base pairs and 2 nt sticky ends containing a semi-junction that becomes left-handed
Experimental procedure
| Experimental method | SINGLE WAVELENGTH |
| Source type | SYNCHROTRON |
| Source details | APS BEAMLINE 17-ID |
| Synchrotron site | APS |
| Beamline | 17-ID |
| Temperature [K] | 100 |
| Detector technology | PIXEL |
| Collection date | 2022-10-16 |
| Detector | DECTRIS EIGER X 9M |
| Wavelength(s) | 1.000010 |
| Spacegroup name | H 3 |
| Unit cell lengths | 112.173, 112.173, 67.872 |
| Unit cell angles | 90.00, 90.00, 120.00 |
Refinement procedure
| Resolution | 32.380 - 4.880 |
| R-factor | 0.1879 |
| Rwork | 0.186 |
| R-free | 0.21350 |
| Structure solution method | MOLECULAR REPLACEMENT |
| RMSD bond length | 0.004 |
| RMSD bond angle | 0.682 |
| Data reduction software | autoPROC |
| Data scaling software | STARANISO |
| Phasing software | PHASER |
| Refinement software | PHENIX (1.21.1_5286) |
Data quality characteristics
| Overall | Inner shell | Outer shell | |
| Low resolution limit [Å] | 56.087 | 56.086 | 5.353 |
| High resolution limit [Å] | 4.877 | 9.725 | 4.877 |
| Number of reflections | 1316 | 186 | 189 |
| <I/σ(I)> | 9.4 | ||
| Completeness [%] | 89.3 | ||
| Redundancy | 9.1 | ||
| CC(1/2) | 0.999 | 0.999 | 0.310 |
Crystallization Conditions
| crystal ID | method | pH | temperature | details |
| 1 | VAPOR DIFFUSION, HANGING DROP | 293 | 100 mM MOPS, 1.25 M magnesium sulfate |