9NGD
cis-CaaD/Cg10062 chimera
Experimental procedure
| Experimental method | SINGLE WAVELENGTH |
| Source type | SYNCHROTRON |
| Source details | APS BEAMLINE 21-ID-D |
| Synchrotron site | APS |
| Beamline | 21-ID-D |
| Temperature [K] | 100 |
| Detector technology | PIXEL |
| Collection date | 2022-07-30 |
| Detector | DECTRIS EIGER2 S 9M |
| Wavelength(s) | 0.98 |
| Spacegroup name | P 63 |
| Unit cell lengths | 59.828, 59.828, 57.111 |
| Unit cell angles | 90.00, 90.00, 120.00 |
Refinement procedure
| Resolution | 38.370 - 2.700 |
| R-factor | 0.2492 |
| Rwork | 0.239 |
| R-free | 0.33610 |
| Structure solution method | MOLECULAR REPLACEMENT |
| RMSD bond length | 0.009 |
| RMSD bond angle | 1.189 |
| Data reduction software | HKL-2000 |
| Data scaling software | HKL-2000 |
| Phasing software | PHASER |
| Refinement software | PHENIX (1.21.2_5419) |
Data quality characteristics
| Overall | Outer shell | |
| Low resolution limit [Å] | 50.000 | 2.750 |
| High resolution limit [Å] | 2.700 | 2.700 |
| Rpim | 0.059 | 0.143 |
| Number of reflections | 2758 | 160 |
| <I/σ(I)> | 12.27 | |
| Completeness [%] | 83.3 | |
| Redundancy | 4.9 |
Crystallization Conditions
| crystal ID | method | pH | temperature | details |
| 1 | VAPOR DIFFUSION, HANGING DROP | 296 | 0.2 M lithium chloride 20% w/v PEG 3,350 |