9NGD
cis-CaaD/Cg10062 chimera
Experimental procedure
Experimental method | SINGLE WAVELENGTH |
Source type | SYNCHROTRON |
Source details | APS BEAMLINE 21-ID-D |
Synchrotron site | APS |
Beamline | 21-ID-D |
Temperature [K] | 100 |
Detector technology | PIXEL |
Collection date | 2022-07-30 |
Detector | DECTRIS EIGER2 S 9M |
Wavelength(s) | 0.98 |
Spacegroup name | P 63 |
Unit cell lengths | 59.828, 59.828, 57.111 |
Unit cell angles | 90.00, 90.00, 120.00 |
Refinement procedure
Resolution | 38.370 - 2.700 |
R-factor | 0.2492 |
Rwork | 0.239 |
R-free | 0.33610 |
Structure solution method | MOLECULAR REPLACEMENT |
RMSD bond length | 0.009 |
RMSD bond angle | 1.189 |
Data reduction software | HKL-2000 |
Data scaling software | HKL-2000 |
Phasing software | PHASER |
Refinement software | PHENIX (1.21.2_5419) |
Data quality characteristics
Overall | Outer shell | |
Low resolution limit [Å] | 50.000 | 2.750 |
High resolution limit [Å] | 2.700 | 2.700 |
Rpim | 0.059 | 0.143 |
Number of reflections | 2758 | 160 |
<I/σ(I)> | 12.27 | |
Completeness [%] | 83.3 | |
Redundancy | 4.9 |
Crystallization Conditions
crystal ID | method | pH | temperature | details |
1 | VAPOR DIFFUSION, HANGING DROP | 296 | 0.2 M lithium chloride 20% w/v PEG 3,350 |