9NF1

cis-CaaD E114D mutant

Experimental procedure
Experimental methodSINGLE WAVELENGTH
Source typeSYNCHROTRON
Source detailsAPS BEAMLINE 21-ID-D
Synchrotron siteAPS
Beamline21-ID-D
Temperature [K]100
Detector technologyPIXEL
Collection date2021-07-09
DetectorDECTRIS EIGER2 S 9M
Wavelength(s)1.13
Spacegroup nameC 2 2 21
Unit cell lengths59.997, 100.294, 147.226
Unit cell angles90.00, 90.00, 90.00
Refinement procedure
Resolution29.200 - 1.600
R-factor0.1777
Rwork0.176
R-free0.21960
Structure solution methodMOLECULAR REPLACEMENT
RMSD bond length0.007
RMSD bond angle0.970
Data reduction softwareHKL-2000
Data scaling softwareHKL-2000
Phasing softwarePHASER
Refinement softwarePHENIX (1.19.2_4158)
Data quality characteristics
 OverallOuter shell
Low resolution limit [Å]50.0001.630
High resolution limit [Å]1.6001.600
Rpim0.0230.309
Number of reflections523662769
<I/σ(I)>26.63
Completeness [%]88.9
Redundancy7.2
Crystallization Conditions
crystal IDmethodpHtemperaturedetails
1VAPOR DIFFUSION, HANGING DROP2960.2 M ammonium sulfate 20% w/v PEG 3,351