Reduced state of a turn-off thiol-disulfide redox biosensor with a fluorescence-lifetime readout

Experimental procedure
Experimental methodSINGLE WAVELENGTH
Source typeROTATING ANODE
Source detailsRIGAKU MICROMAX-007
Temperature [K]100
Detector technologyCCD
Collection date2023-04-25
DetectorRIGAKU SATURN 944
Wavelength(s)1.5418
Spacegroup nameC 2 2 21
Unit cell lengths52.800, 140.180, 130.060
Unit cell angles90.00, 90.00, 90.00
Refinement procedure
Resolution30.850 - 2.000
Rwork0.186
R-free0.22460
Structure solution methodMOLECULAR REPLACEMENT
RMSD bond length0.002
RMSD bond angle1.171
Data reduction softwareXDS
Data scaling softwareXDS
Phasing softwarePHASER
Refinement softwarePHENIX (1.20.1_4487)
Data quality characteristics
 OverallOuter shell
Low resolution limit [Å]30.8502.072
High resolution limit [Å]2.0002.000
Number of reflections3280214547
<I/σ(I)>11.28
Completeness [%]99.1
Redundancy9.1
CC(1/2)0.9970.664
Crystallization Conditions
crystal IDmethodpHtemperaturedetails
1VAPOR DIFFUSION, HANGING DROP2982.5% glycerol, 5% Tacsimate (pH 4.0), 0.1 M sodium acetate (pH 5.2), 16% PEG 3350, 10 mM TCEP (pH ~7.0)

246031

PDB entries from 2025-12-10

PDB statisticsPDBj update infoContact PDBjnumon