9LOA
Structural insights into the tumor suppressor ZMYND11 reveal diverse recognition mechanisms
Experimental procedure
| Experimental method | SINGLE WAVELENGTH |
| Source type | SYNCHROTRON |
| Source details | SSRF BEAMLINE BL02U1 |
| Synchrotron site | SSRF |
| Beamline | BL02U1 |
| Temperature [K] | 198 |
| Detector technology | PIXEL |
| Collection date | 2024-09-16 |
| Detector | DECTRIS EIGER X 16M |
| Wavelength(s) | 0.9793 |
| Spacegroup name | P 61 2 2 |
| Unit cell lengths | 102.878, 102.878, 84.286 |
| Unit cell angles | 90.00, 90.00, 120.00 |
Refinement procedure
| Resolution | 32.620 - 1.800 |
| R-factor | 0.14583 |
| Rwork | 0.144 |
| R-free | 0.17285 |
| Structure solution method | AB INITIO PHASING |
| RMSD bond length | 0.010 |
| RMSD bond angle | 1.516 |
| Data reduction software | HKL-2000 |
| Data scaling software | HKL-2000 |
| Phasing software | BALBES |
| Refinement software | REFMAC (5.8.0267) |
Data quality characteristics
| Overall | Outer shell | |
| Low resolution limit [Å] | 50.000 | 1.830 |
| High resolution limit [Å] | 1.800 | 1.800 |
| Number of reflections | 24893 | 24893 |
| <I/σ(I)> | 2.29 | |
| Completeness [%] | 99.9 | |
| Redundancy | 17.9 | |
| CC(1/2) | 1.000 | 1.000 |
Crystallization Conditions
| crystal ID | method | pH | temperature | details |
| 1 | VAPOR DIFFUSION, SITTING DROP | 7.5 | 289 | 20% PEG 1500, 200 mM MgCl2, 100 mM Na CaCo pH 5.5 |