Experimental procedure
| Experimental method | SINGLE WAVELENGTH |
| Source type | SYNCHROTRON |
| Source details | SSRF BEAMLINE BL10U2 |
| Synchrotron site | SSRF |
| Beamline | BL10U2 |
| Temperature [K] | 100 |
| Detector technology | CCD |
| Collection date | 2023-09-24 |
| Detector | RAYONIX MX300HE |
| Wavelength(s) | 0.987 |
| Spacegroup name | P 65 2 2 |
| Unit cell lengths | 58.620, 58.620, 221.940 |
| Unit cell angles | 90.00, 90.00, 120.00 |
Refinement procedure
| Resolution | 29.310 - 1.950 |
| R-factor | 0.2106 |
| Rwork | 0.209 |
| R-free | 0.23960 |
| Structure solution method | MOLECULAR REPLACEMENT |
| RMSD bond length | 0.008 |
| RMSD bond angle | 1.094 |
| Data reduction software | xia2 |
| Data scaling software | xia2 |
| Phasing software | PHASER |
| Refinement software | PHENIX ((1.19.1_4122: ???)) |
Data quality characteristics
| Overall | Outer shell | |
| Low resolution limit [Å] | 29.900 | 2.000 |
| High resolution limit [Å] | 1.950 | 1.950 |
| Rmerge | 0.107 | 1.304 |
| Rmeas | 0.108 | 1.338 |
| Rpim | 0.019 | 0.296 |
| Number of reflections | 17512 | 1227 |
| <I/σ(I)> | 23.6 | 3 |
| Completeness [%] | 100.0 | |
| Redundancy | 31.7 | |
| CC(1/2) | 0.999 | 0.795 |
Crystallization Conditions
| crystal ID | method | pH | temperature | details |
| 1 | VAPOR DIFFUSION, HANGING DROP | 4.8 | 300 | 200 mM Potassium phosphate monobasic 20% w/v PEG 3350 pH 4.8 |