9KMO
HR1 domain from HCoV-OC43 in complex with a pan-CoV inhibitor EK1
Experimental procedure
| Experimental method | SINGLE WAVELENGTH |
| Source type | SYNCHROTRON |
| Source details | SSRF BEAMLINE BL17U1 |
| Synchrotron site | SSRF |
| Beamline | BL17U1 |
| Temperature [K] | 100 |
| Detector technology | CMOS |
| Collection date | 2019-03-14 |
| Detector | BRUKER PHOTON 100 |
| Wavelength(s) | 0.97930 |
| Spacegroup name | P 3 |
| Unit cell lengths | 53.014, 53.014, 62.175 |
| Unit cell angles | 90.00, 90.00, 120.00 |
Refinement procedure
| Resolution | 25.740 - 2.700 |
| Rwork | 0.282 |
| R-free | 0.31100 |
| Structure solution method | MOLECULAR REPLACEMENT |
| Data reduction software | HKL-3000 |
| Data scaling software | xia2 |
| Phasing software | PHENIX |
| Refinement software | PHENIX (1.16_3549) |
Data quality characteristics
| Overall | Outer shell | |
| Low resolution limit [Å] | 25.740 | 2.800 |
| High resolution limit [Å] | 2.700 | 2.700 |
| Number of reflections | 5336 | 548 |
| <I/σ(I)> | 2 | |
| Completeness [%] | 99.6 | |
| Redundancy | 3 | |
| CC(1/2) | 0.800 | 0.600 |
Crystallization Conditions
| crystal ID | method | pH | temperature | details |
| 1 | VAPOR DIFFUSION, HANGING DROP | 298 | 0.2 M MgCl2, 0.1 M TRIS pH 8.5, and 30% PEG 4K |