Loading
PDBj
MenuPDBj@FacebookPDBj@X(formerly Twitter)PDBj@BlueSkyPDBj@YouTubewwPDB FoundationwwPDBDonate
RCSB PDBPDBeBMRBAdv. SearchSearch help

9KFB

RABV-G-ecto/NM57-scFv complex

Experimental procedure
Experimental methodSINGLE WAVELENGTH
Source typeSYNCHROTRON
Source detailsSSRF BEAMLINE BL17U1
Synchrotron siteSSRF
BeamlineBL17U1
Temperature [K]100
Detector technologyPIXEL
Collection date2017-12-21
DetectorDECTRIS PILATUS3 6M
Wavelength(s)0.97925
Spacegroup nameP 41 21 2
Unit cell lengths157.619, 157.619, 221.392
Unit cell angles90.00, 90.00, 90.00
Refinement procedure
Resolution36.640 - 4.300
R-factor0.2634
Rwork0.261
R-free0.31430
Structure solution methodMOLECULAR REPLACEMENT
RMSD bond length0.007
RMSD bond angle1.102
Data reduction softwareDENZO
Data scaling softwareHKL-3000
Phasing softwarePHASER
Refinement softwarePHENIX ((1.20.1_4487: ???))
Data quality characteristics
 OverallOuter shell
Low resolution limit [Å]50.0004.450
High resolution limit [Å]4.2804.300
Rmerge0.2261.847
Number of reflections198231936
<I/σ(I)>24.96
Completeness [%]99.8
Redundancy24.5
Crystallization Conditions
crystal IDmethodpHtemperaturedetails
1VAPOR DIFFUSION, SITTING DROP2890.2 M Ammonium sulfate, 0.1 M Sodium acetate (pH 5.5), 10 % w/v PEG 2000 MME

245663

PDB entries from 2025-12-03

PDB statisticsPDBj update infoContact PDBjnumon