Experimental procedure
| Experimental method | SINGLE WAVELENGTH |
| Source type | SYNCHROTRON |
| Source details | SSRF BEAMLINE BL19U1 |
| Synchrotron site | SSRF |
| Beamline | BL19U1 |
| Temperature [K] | 100 |
| Detector technology | PIXEL |
| Collection date | 2024-06-22 |
| Detector | DECTRIS PILATUS3 6M |
| Wavelength(s) | 0.979230 |
| Spacegroup name | P 21 21 21 |
| Unit cell lengths | 56.265, 89.669, 128.464 |
| Unit cell angles | 90.00, 90.00, 90.00 |
Refinement procedure
| Resolution | 47.660 - 1.760 |
| R-factor | 0.2137 |
| Rwork | 0.212 |
| R-free | 0.25260 |
| Structure solution method | MOLECULAR REPLACEMENT |
| RMSD bond length | 0.006 |
| RMSD bond angle | 0.765 |
| Data reduction software | XDS |
| Data scaling software | XDS |
| Phasing software | PHASER |
| Refinement software | PHENIX ((1.21.1_5286: ???)) |
Data quality characteristics
| Overall | Outer shell | |
| Low resolution limit [Å] | 47.660 | 1.823 |
| High resolution limit [Å] | 1.760 | 1.760 |
| Number of reflections | 65191 | 6425 |
| <I/σ(I)> | 23.5 | |
| Completeness [%] | 98.1 | |
| Redundancy | 10.165 | |
| CC(1/2) | 0.999 | 0.879 |
Crystallization Conditions
| crystal ID | method | pH | temperature | details |
| 1 | VAPOR DIFFUSION, HANGING DROP | 291 | PEG3350, Bis-Tris, Ammonium sulfate |