Experimental procedure
Experimental method | SINGLE WAVELENGTH |
Source type | SYNCHROTRON |
Source details | SSRF BEAMLINE BL17U1 |
Synchrotron site | SSRF |
Beamline | BL17U1 |
Temperature [K] | 100 |
Detector technology | CCD |
Collection date | 2019-10-19 |
Detector | ADSC QUANTUM 315 |
Wavelength(s) | 0.97921 |
Spacegroup name | P 21 21 21 |
Unit cell lengths | 59.390, 90.380, 170.900 |
Unit cell angles | 90.00, 90.00, 90.00 |
Refinement procedure
Resolution | 50.000 - 2.870 |
R-factor | 0.22811 |
Rwork | 0.225 |
R-free | 0.28230 |
Structure solution method | MOLECULAR REPLACEMENT |
Starting model (for MR) | 6jue |
RMSD bond length | 0.007 |
RMSD bond angle | 1.352 |
Data reduction software | XDS |
Data scaling software | XDS |
Phasing software | PHASER |
Refinement software | REFMAC (5.8.0405) |
Data quality characteristics
Overall | Outer shell | |
Low resolution limit [Å] | 62.090 | 2.940 |
High resolution limit [Å] | 2.870 | 2.870 |
Rmerge | 0.091 | 1.117 |
Number of reflections | 20641 | 20641 |
<I/σ(I)> | 21.3 | 2.7 |
Completeness [%] | 99.9 | 100 |
Redundancy | 13 | 13.9 |
CC(1/2) | 0.999 | 0.847 |
Crystallization Conditions
crystal ID | method | pH | temperature | details |
1 | VAPOR DIFFUSION, HANGING DROP | 4 | 289.15 | 1.8 M ammonium sulfate, 0.1 M citrate (pH 4.0) |