Experimental procedure
| Experimental method | SINGLE WAVELENGTH |
| Source type | SYNCHROTRON |
| Source details | DIAMOND BEAMLINE I04 |
| Synchrotron site | Diamond |
| Beamline | I04 |
| Temperature [K] | 100 |
| Detector technology | PIXEL |
| Collection date | 2025-02-03 |
| Detector | DECTRIS PILATUS 6M |
| Wavelength(s) | 0.95374 |
| Spacegroup name | P 43 21 2 |
| Unit cell lengths | 74.887, 74.887, 253.173 |
| Unit cell angles | 90.00, 90.00, 90.00 |
Refinement procedure
| Resolution | 34.230 - 1.721 |
| R-factor | 0.2262 |
| Rwork | 0.226 |
| R-free | 0.24040 |
| Structure solution method | MOLECULAR REPLACEMENT |
| RMSD bond length | 0.009 |
| RMSD bond angle | 0.850 |
| Data reduction software | autoPROC |
| Data scaling software | autoPROC |
| Phasing software | PHASER |
| Refinement software | BUSTER (2.11.8) |
Data quality characteristics
| Overall | Outer shell | |
| Low resolution limit [Å] | 71.811 | 1.893 |
| High resolution limit [Å] | 1.721 | 1.721 |
| Number of reflections | 55740 | 2787 |
| <I/σ(I)> | 16.9 | |
| Completeness [%] | 95.4 | |
| Redundancy | 15.1 | |
| CC(1/2) | 0.998 | 0.880 |
Crystallization Conditions
| crystal ID | method | pH | temperature | details |
| 1 | VAPOR DIFFUSION, SITTING DROP | 293 | 15 % PEG8000, 0.1 M PCTP pH 8.5 |