Loading
PDBj
MenuPDBj@FacebookPDBj@X(formerly Twitter)PDBj@BlueSkyPDBj@YouTubewwPDB FoundationwwPDBDonate
RCSB PDBPDBeBMRBAdv. SearchSearch help

9H5F

MITF(217-296)

Experimental procedure
Experimental methodSINGLE WAVELENGTH
Source typeSYNCHROTRON
Source detailsSLS BEAMLINE X10SA
Synchrotron siteSLS
BeamlineX10SA
Temperature [K]100
Detector technologyPIXEL
Collection date2019-07-03
DetectorDECTRIS EIGER X 16M
Wavelength(s)1.00002
Spacegroup nameP 41 21 2
Unit cell lengths90.640, 90.640, 82.773
Unit cell angles90.00, 90.00, 90.00
Refinement procedure
Resolution64.090 - 2.300
R-factor0.2318
Rwork0.231
R-free0.25500
Structure solution methodMOLECULAR REPLACEMENT
RMSD bond length0.001
RMSD bond angle0.289
Data reduction softwareautoPROC
Data scaling softwareautoPROC
Phasing softwarePHASER
Refinement softwarePHENIX (1.21.2_5419)
Data quality characteristics
 OverallOuter shell
Low resolution limit [Å]64.0922.340
High resolution limit [Å]2.3002.300
Rpim0.0260.244
Number of reflections15627749
<I/σ(I)>18.7
Completeness [%]98.5
Redundancy13
CC(1/2)0.9990.874
Crystallization Conditions
crystal IDmethodpHtemperaturedetails
1VAPOR DIFFUSION, SITTING DROP2932.2 M ammonium sulfate, 5 % (v/v) PEG 400, 0.1 M MES pH 6.5

252091

PDB entries from 2026-04-15