Experimental procedure
| Experimental method | SINGLE WAVELENGTH |
| Source type | SYNCHROTRON |
| Source details | ESRF BEAMLINE ID23-1 |
| Synchrotron site | ESRF |
| Beamline | ID23-1 |
| Temperature [K] | 80 |
| Detector technology | PIXEL |
| Collection date | 2023-05-05 |
| Detector | DECTRIS EIGER X 16M |
| Wavelength(s) | 0.97626 |
| Spacegroup name | I 4 2 2 |
| Unit cell lengths | 108.703, 108.703, 209.157 |
| Unit cell angles | 90.00, 90.00, 90.00 |
Refinement procedure
| Resolution | 48.200 - 2.200 |
| Rwork | 0.221 |
| R-free | 0.25200 |
| Structure solution method | MOLECULAR REPLACEMENT |
| RMSD bond length | 0.013 |
| RMSD bond angle | 2.127 |
| Data reduction software | xia2 |
| Data scaling software | Aimless |
| Phasing software | PHASER |
| Refinement software | REFMAC (5.8.0425) |
Data quality characteristics
| Overall | Outer shell | |
| Low resolution limit [Å] | 48.200 | 9.000 |
| High resolution limit [Å] | 2.200 | 2.200 |
| Number of reflections | 32204 | 2748 |
| <I/σ(I)> | 28.6 | 4.5 |
| Completeness [%] | 100.0 | 100 |
| Redundancy | 20 | |
| CC(1/2) | 1.000 | 0.973 |
Crystallization Conditions
| crystal ID | method | pH | temperature | details |
| 1 | VAPOR DIFFUSION, SITTING DROP | 7.5 | 277 | 30.8% PEG300 100mM HEPES 100mM NaCl |