Experimental procedure
| Experimental method | SINGLE WAVELENGTH |
| Source type | SYNCHROTRON |
| Source details | MAX IV BEAMLINE BioMAX |
| Synchrotron site | MAX IV |
| Beamline | BioMAX |
| Temperature [K] | 100 |
| Detector technology | PIXEL |
| Collection date | 2023-05-31 |
| Detector | DECTRIS EIGER X 16M |
| Wavelength(s) | 0.826561 |
| Spacegroup name | P 1 21 1 |
| Unit cell lengths | 37.530, 32.850, 120.600 |
| Unit cell angles | 90.00, 94.74, 90.00 |
Refinement procedure
| Resolution | 40.063 - 1.100 |
| Rwork | 0.155 |
| R-free | 0.17480 |
| Structure solution method | MOLECULAR REPLACEMENT |
| RMSD bond length | 0.009 |
| RMSD bond angle | 1.501 |
| Data reduction software | XDS |
| Data scaling software | XSCALE |
| Phasing software | PHASER |
| Refinement software | REFMAC (5.8.0267) |
Data quality characteristics
| Overall | Outer shell | |
| Low resolution limit [Å] | 40.063 | 1.130 |
| High resolution limit [Å] | 1.100 | 1.100 |
| Rmeas | 0.056 | |
| Number of reflections | 119450 | 8807 |
| <I/σ(I)> | 15.34 | 1.99 |
| Completeness [%] | 100.0 | 100 |
| Redundancy | 6.75 | 6.72 |
| CC(1/2) | 1.000 | 0.713 |
Crystallization Conditions
| crystal ID | method | pH | temperature | details |
| 1 | VAPOR DIFFUSION, SITTING DROP | 9.5 | 298 | 0.1 M CHES pH 9.5, 32% PEG (w/v) 3000 |