Experimental procedure
| Experimental method | SINGLE WAVELENGTH |
| Source type | SYNCHROTRON |
| Source details | ESRF BEAMLINE ID23-2 |
| Synchrotron site | ESRF |
| Beamline | ID23-2 |
| Temperature [K] | 100 |
| Detector technology | PIXEL |
| Collection date | 2023-05-06 |
| Detector | DECTRIS EIGER2 XE 9M |
| Wavelength(s) | 0.873 |
| Spacegroup name | C 1 2 1 |
| Unit cell lengths | 111.110, 34.501, 55.338 |
| Unit cell angles | 90.00, 95.86, 90.00 |
Refinement procedure
| Resolution | 37.150 - 2.300 |
| R-factor | 0.2145 |
| Rwork | 0.213 |
| R-free | 0.24440 |
| Structure solution method | MOLECULAR REPLACEMENT |
| RMSD bond length | 0.003 |
| RMSD bond angle | 0.458 |
| Data reduction software | autoPROC |
| Data scaling software | Aimless |
| Phasing software | PHASER |
| Refinement software | PHENIX (1.21.1-5286) |
Data quality characteristics
| Overall | Outer shell | |
| Low resolution limit [Å] | 55.265 | 2.355 |
| High resolution limit [Å] | 2.141 | 2.141 |
| Rmerge | 0.198 | 1.751 |
| Number of reflections | 25602 | 1388 |
| <I/σ(I)> | 4.7 | |
| Completeness [%] | 85.9 | |
| Redundancy | 4.7 |
Crystallization Conditions
| crystal ID | method | pH | temperature | details |
| 1 | VAPOR DIFFUSION, SITTING DROP | 277 | 70 % MPD, 100 mM HEPES pH 7.5 |