Experimental procedure
| Experimental method | SINGLE WAVELENGTH |
| Source type | SYNCHROTRON |
| Source details | DIAMOND BEAMLINE I04 |
| Synchrotron site | Diamond |
| Beamline | I04 |
| Temperature [K] | 100 |
| Detector technology | PIXEL |
| Collection date | 2018-11-30 |
| Detector | DECTRIS PILATUS 6M |
| Wavelength(s) | 0.97626 |
| Spacegroup name | P 21 21 21 |
| Unit cell lengths | 52.947, 71.134, 72.079 |
| Unit cell angles | 90.00, 90.00, 90.00 |
Refinement procedure
| Resolution | 13.240 - 1.160 |
| R-factor | 0.204 |
| Rwork | 0.203 |
| R-free | 0.22480 |
| Structure solution method | MOLECULAR REPLACEMENT |
| RMSD bond length | 0.014 |
| RMSD bond angle | 1.230 |
| Data reduction software | autoPROC |
| Data scaling software | autoPROC |
| Phasing software | PHASER |
| Refinement software | BUSTER (2.11.8) |
Data quality characteristics
| Overall | Outer shell | |
| Low resolution limit [Å] | 42.672 | 1.270 |
| High resolution limit [Å] | 1.160 | 1.160 |
| Rmeas | 0.055 | 1.210 |
| Number of reflections | 70554 | 22993 |
| <I/σ(I)> | 10.7 | 1.7 |
| Completeness [%] | 99.7 | |
| Redundancy | 6.3 | 4.8 |
| CC(1/2) | 0.998 | 0.254 |
Crystallization Conditions
| crystal ID | method | pH | temperature | details |
| 1 | VAPOR DIFFUSION, SITTING DROP | 293 | 8.5% PEG3350, 0.1M HEPES pH 7.5 |