Experimental procedure
| Experimental method | SINGLE WAVELENGTH |
| Source type | SYNCHROTRON |
| Source details | ESRF BEAMLINE ID23-1 |
| Synchrotron site | ESRF |
| Beamline | ID23-1 |
| Temperature [K] | 298 |
| Detector technology | PIXEL |
| Collection date | 2022-11-10 |
| Detector | DECTRIS EIGER2 XE CdTe 16M |
| Wavelength(s) | 0.87313 |
| Spacegroup name | P 41 21 2 |
| Unit cell lengths | 47.222, 47.222, 142.039 |
| Unit cell angles | 90.00, 90.00, 90.00 |
Refinement procedure
| Resolution | 33.430 - 1.213 |
| Rwork | 0.177 |
| R-free | 0.19890 |
| Structure solution method | MOLECULAR REPLACEMENT |
| RMSD bond length | 0.016 |
| RMSD bond angle | 1.916 |
| Data reduction software | autoPROC |
| Data scaling software | autoPROC |
| Refinement software | REFMAC (5.8.0267) |
Data quality characteristics
| Overall | Outer shell | |
| Low resolution limit [Å] | 33.430 | 1.256 |
| High resolution limit [Å] | 1.213 | 1.213 |
| Rmeas | 0.022 | 0.345 |
| Number of reflections | 49774 | 4863 |
| <I/σ(I)> | 15.16 | 2.32 |
| Completeness [%] | 100.0 | 100 |
| Redundancy | 2 | 2 |
| CC(1/2) | 1.000 | 0.836 |
Crystallization Conditions
| crystal ID | method | pH | temperature | details |
| 1 | VAPOR DIFFUSION, HANGING DROP | 6.5 | 293 | 0.1M NaCl, 0.1M Bis-Tris pH 6.5, 1.5M Ammonium sulfate. |