9GF2
CC-Hex-hen2 variant peptide with Hendecad repeat substitution
Experimental procedure
Experimental method | SINGLE WAVELENGTH |
Source type | SYNCHROTRON |
Source details | DIAMOND BEAMLINE I04 |
Synchrotron site | Diamond |
Beamline | I04 |
Temperature [K] | 100 |
Detector technology | PIXEL |
Collection date | 2021-10-01 |
Detector | DECTRIS EIGER2 XE 16M |
Wavelength(s) | 0.9795 |
Spacegroup name | P 2 21 21 |
Unit cell lengths | 48.563, 58.157, 59.258 |
Unit cell angles | 90.00, 90.00, 90.00 |
Refinement procedure
Resolution | 48.610 - 2.099 |
Rwork | 0.224 |
R-free | 0.29250 |
Structure solution method | AB INITIO PHASING |
RMSD bond length | 0.019 |
RMSD bond angle | 2.694 |
Data reduction software | DIALS |
Data scaling software | DIALS |
Phasing software | PHASER |
Refinement software | REFMAC (5.8.0425) |
Data quality characteristics
Overall | Outer shell | |
Low resolution limit [Å] | 48.610 | 2.160 |
High resolution limit [Å] | 2.099 | 2.100 |
Rmerge | 0.011 | 0.071 |
Rmeas | 0.015 | 0.101 |
Rpim | 0.011 | 0.071 |
Number of reflections | 10287 | 812 |
<I/σ(I)> | 26.6 | 4.7 |
Completeness [%] | 100.0 | 99.9 |
Redundancy | 1.8 | 1.9 |
CC(1/2) | 1.000 | 0.986 |
Crystallization Conditions
crystal ID | method | pH | temperature | details |
1 | VAPOR DIFFUSION, SITTING DROP | 293 | 0.2 M Ammonium Acetate, 0.1 M BIS-Tris, pH 5.5, 25% w/v PEG 3350 |