9FPG
Ni,Fe-CODH : Ti(III)-reduced pH 6.0
Experimental procedure
Experimental method | SINGLE WAVELENGTH |
Source type | SYNCHROTRON |
Source details | BESSY BEAMLINE 14.2 |
Synchrotron site | BESSY |
Beamline | 14.2 |
Temperature [K] | 100 |
Detector technology | PIXEL |
Collection date | 2024-02-02 |
Detector | DECTRIS PILATUS3 S 2M |
Wavelength(s) | 0.91841 |
Spacegroup name | C 1 2 1 |
Unit cell lengths | 112.400, 75.460, 71.160 |
Unit cell angles | 90.00, 111.30, 90.00 |
Refinement procedure
Resolution | 35.320 - 1.310 |
R-factor | 0.1456 |
Rwork | 0.145 |
R-free | 0.15800 |
Structure solution method | MOLECULAR REPLACEMENT |
RMSD bond length | 0.007 |
RMSD bond angle | 1.029 |
Data reduction software | XDS |
Data scaling software | XSCALE |
Phasing software | PHASER |
Refinement software | PHENIX ((1.21_5207: ???)) |
Data quality characteristics
Overall | Outer shell | |
Low resolution limit [Å] | 40.880 | 1.360 |
High resolution limit [Å] | 1.310 | 1.310 |
Rmerge | 0.105 | |
Rmeas | 0.113 | |
Number of reflections | 131410 | 12934 |
<I/σ(I)> | 10.1 | |
Completeness [%] | 99.1 | |
Redundancy | 6.8 | |
CC(1/2) | 0.999 | 0.320 |
Crystallization Conditions
crystal ID | method | pH | temperature | details |
1 | VAPOR DIFFUSION, HANGING DROP | 7.5 | 291.15 | 0.1M HEPES pH 7.5, PEG 2000MME 14-18% |