9F56
Identification of calcium ions in thermolysin.
Experimental procedure
Experimental method | SINGLE WAVELENGTH |
Source type | SYNCHROTRON |
Source details | DIAMOND BEAMLINE I23 |
Synchrotron site | Diamond |
Beamline | I23 |
Temperature [K] | 80 |
Detector technology | PIXEL |
Collection date | 2024-02-22 |
Detector | DECTRIS PILATUS 12M |
Wavelength(s) | 3.06892 |
Spacegroup name | P 61 2 2 |
Unit cell lengths | 93.151, 93.151, 128.981 |
Unit cell angles | 90.00, 90.00, 120.00 |
Refinement procedure
Resolution | 80.670 - 2.100 |
R-factor | 0.18255 |
Rwork | 0.181 |
R-free | 0.21900 |
Structure solution method | MOLECULAR REPLACEMENT |
RMSD bond length | 0.003 |
RMSD bond angle | 1.167 |
Data reduction software | DIALS |
Data scaling software | DIALS |
Phasing software | PHASER |
Refinement software | REFMAC (5.8.0425) |
Data quality characteristics
Overall | Outer shell | |
Low resolution limit [Å] | 129.400 | 2.140 |
High resolution limit [Å] | 2.100 | 2.100 |
Rmeas | 0.110 | 0.270 |
Number of reflections | 20017 | 966 |
<I/σ(I)> | 19.3 | 4.2 |
Completeness [%] | 100.0 | |
Redundancy | 22.8 | |
CC(1/2) | 0.990 | 0.980 |
Crystallization Conditions
crystal ID | method | pH | temperature | details |
1 | VAPOR DIFFUSION, SITTING DROP | 6 | 293 | 1.2 M Ammonium Sulphate |
1 | VAPOR DIFFUSION, SITTING DROP | 6 | 293 | 1.2 M Ammonium Sulphate |