Loading
PDBj
MenuPDBj@FacebookPDBj@TwitterPDBj@YouTubewwPDB FoundationwwPDB
RCSB PDBPDBeBMRBAdv. SearchSearch help

9F4J

UP1 in complex with Z416341642

Experimental procedure
Experimental methodSINGLE WAVELENGTH
Source typeSYNCHROTRON
Source detailsDIAMOND BEAMLINE I04-1
Synchrotron siteDiamond
BeamlineI04-1
Temperature [K]100
Detector technologyPIXEL
Collection date2018-06-29
DetectorDECTRIS PILATUS 6M-F
Wavelength(s)0.91587
Spacegroup nameP 1 21 1
Unit cell lengths38.006, 43.900, 56.009
Unit cell angles90.00, 94.22, 90.00
Refinement procedure
Resolution34.520 - 1.400
R-factor0.1832
Rwork0.182
R-free0.19830
Structure solution methodMOLECULAR REPLACEMENT
RMSD bond length0.008
RMSD bond angle1.060
Data reduction softwarexia2
Data scaling softwareAimless
Phasing softwarePHASER
Refinement softwarePHENIX (1.20.1_4487)
Data quality characteristics
 OverallOuter shell
Low resolution limit [Å]34.5201.420
High resolution limit [Å]1.4001.400
Rmerge0.0320.394
Rmeas0.0450.558
Rpim0.0320.394
Total number of observations618462099
Number of reflections352051452
<I/σ(I)>10.51.6
Completeness [%]96.8
Redundancy1.81.4
CC(1/2)0.9980.704
Crystallization Conditions
crystal IDmethodpHtemperaturedetails
1VAPOR DIFFUSION, SITTING DROP8.52890.1 M Tris-HCl, pH 8.50, 25% PEG-4000, 8% 2-Methyl-2,4-pentanediol

225946

PDB entries from 2024-10-09