Loading
PDBj
MenuPDBj@FacebookPDBj@TwitterPDBj@YouTubewwPDB FoundationwwPDB
RCSB PDBPDBeBMRBAdv. SearchSearch help

9EUR

Mpro WT from SARS-CoV-2 with 298Q mutation

Experimental procedure
Experimental methodSINGLE WAVELENGTH
Source typeSYNCHROTRON
Source detailsBESSY BEAMLINE 14.1
Synchrotron siteBESSY
Beamline14.1
Temperature [K]100
Detector technologyPIXEL
Collection date2022-11-01
DetectorDECTRIS PILATUS3 S 6M
Wavelength(s)1.03320
Spacegroup nameI 1 2 1
Unit cell lengths44.979, 53.680, 113.957
Unit cell angles90.00, 100.82, 90.00
Refinement procedure
Resolution48.402 - 2.113
Rwork0.210
R-free0.28060
Structure solution methodMOLECULAR REPLACEMENT
RMSD bond length0.006
RMSD bond angle1.652
Data reduction softwareXDS
Data scaling softwareAimless
Phasing softwarePHASER
Refinement softwareREFMAC (5.8.0425)
Data quality characteristics
 OverallInner shellOuter shell
Low resolution limit [Å]48.40248.4022.170
High resolution limit [Å]2.1108.9602.110
Rmerge0.1370.0712.153
Rmeas0.1620.0842.538
Rpim0.0860.0431.328
Number of reflections152792161246
<I/σ(I)>7.6
Completeness [%]99.1
Redundancy6.76.17
CC(1/2)0.9960.9950.439
Crystallization Conditions
crystal IDmethodpHtemperaturedetails
1VAPOR DIFFUSION, SITTING DROP29320% Polyethylene glycol monomethyl ether 5.000, 200 mM Potassium formate

219869

PDB entries from 2024-05-15

PDB statisticsPDBj update infoContact PDBjnumon